以Cymer公司为例归纳总结了ArF准分子激光器腔放大结构及相应的脉冲能量稳定性的发展历程,讨论了能量放大机制对脉冲能量稳定性的影响,重点分析了MOPRA结构较MOPA结构在能量稳定性方面的优缺点。着重阐述了放电腔内工作气体成分、配比、电极间流速对脉冲能量稳定性的影响以及相应的改善措施,并结合影响脉冲能量稳定性的因素简述能量控制系统在稳定脉冲能量上的应用。
The development of the dual- chamber amplification structure of ArF excimer laser in Cymer was reviewed. Corresponding pulse energy stability was also concluded. The effect of dual- chamber amplification mechanism on pulse energy stability was analyzed. Especially, the MOPRA structure and the MOPA structure are compared. The gas components, proportion of working gases and gas flow rate between electrodes in the discharge chamber,which have strong influence on the pulse energy stability, were also discussed. Corresponding measures were presented to improve energy stability. Finally, the energy servo system was introduced briefly.

[ 可能符合您检索需要的词汇 ]

目的 评估双能量CT(DECT)肾脏成像线性融合方式(LB)中不同加权因子的混合能量图像质量,以确定双能量成像在肾癌诊断中的最佳加权因子.方法 对32例肾癌患者行肾实质期双能量CT扫描,并将140 kV和80 kV两种能量图像进行不同加权因子下的线性融合,比较加权因子从0~1.0混合能量图像的噪声(SD)、信噪比(SNR)、对比噪声比(CNR),并对加权因子分别为0、0.3 ~0.6的图像进行醒目度评分.结果 图像SD在加权因子为0.3、0.4的混合能量图像中较低.图像的SNR和CNR在加权因子为0.4、0.5、0.6的三组混合能量图像中较高,在加权因子为0.6的混合能量图像上最高.加权因子分别为0、0.3、0.4、0.5、0.6的图像质量评分一致性较好,评分总体比较,差异有统计学意义(P<0.05),其中加权因子为0.6的混合能量图像评分最高.结论 肾癌双能量扫描中加权因子为0.6的混合能量图像具有相对较低的SD和较高的SNR、CNR,为肾癌的诊断提供了良好的图像质量保证.
Objective To evaluate the effect of different energy-weighted factors on the CT image quality of dual-energy linear fusion imaging for the diagnosis of renal cell carcinoma so as to determine the best energy-weighted factor.Methods A total of 32 patients with renal cell carcinoma underwent dual-energy CT scanning in renal cortex phase.The images using 140 kV and 80 kV were input to computer for postprocessing,then 8 sets of mixed-energy images were made from 140 kV and 80 kV images with various methods.The background noise,signal-noise rate (SNR) and contrast-noise ratio (CNR) of renal cell carcinoma were determined.The results were compared between each other among 80 kV,0.3LB,140 kV images,which were obtained from mainframe and 8 sets mixed linear blending energy images.The image quality score was ranked among 0.0LB,0.3LB,0.4LB,0.5LB,0.6LB images.Results The noise of 0.3LB and 0.4LB images was lower,with the noise of 0.3LB images being the lowest and the noise of 80 kV imag

[ 可能符合您检索需要的词汇 ]

目的探讨DSCT双能量判断体内结石成分的可行性和准确性。方法收集2012年9月—2013年6月行CT平扫双能量泌尿系检查并经手术证实,红外波普分析的患者118例(结石共127颗)为研究对象,对其予以DSCT双能量扫描后,在工作站(MMWP)上完成结石成分分析;比较外光谱成分分析与DSCT双能量扫描所得结果。结果源CT双能量技术能准确的区分纯尿酸结石和非尿酸结石(敏感性、特异度均为100%),较准确的区分纯草酸钙结石(敏感性为100%,特异度为89.8%),纯羟基磷灰石(敏感性为84.6%,特异度为100%)。结论源CT双能量技术能在治疗前对尿路结石的成分进行初步分析,对尿路结石的预防和治疗有着重要的指导意义。
Objective To investigate the feasibility and accuracy of dual energy DSCT judgment component calculus in vivo. Methods From 2012 September to 2013 June underwent CT scan in dual energy urinary examination and confirmed by operation, 118 patients with infrared pop analysis (stone 127) as the research object, by DSCT dual energy scan on the post, in the worksta-tion (MMWP) on stone composition analysis; analysis and DSCT spectra comparison dual energy scan results. Results Dual ener-gy technique of dual source CT can accurately differentiate between pure uric acid calculi and non uric acid calculi (sensitivity, specificity was 100%), to distinguish pure calcium oxalate stones accurately (sensitivity 100%, specificity 89.8%), pure hydroxyap-atite (sensitivity 84.6%, specificity 100%). Conclusion Dual energy technique of dual source CT can carry on the composition of urinary stones in the treatment of preliminary analysis, has the important guiding significance for the prevention and treat

[ 可能符合您检索需要的词汇 ]

目的:评价双能量CT在痛风性关节炎尿酸盐结晶检出中的作用。方法选出26例痛风性关节炎患者,行双能量CT检查。结果26例痛风性关节炎患者发现36处尿酸盐结晶,第一跖趾关节为最常见沉积部位。结论双能量CT能清楚显示尿酸盐结晶,对痛风性关节炎诊断具有特异性。
Objective To evaluate the effect of dual energy CT in gouty arthritis urate crystal detection . Methods We selected 26 cases of patients with gouty arthritis , for dual energy CT check .Results 26 cases of acute gouty arthritis were found 36 urate crystal, the first metatarsophalangeal joint was the most common site of deposition.Conclusions Dual energy CT can clearly show the urate crystal , on gouty arthritis diagnosis with specificity .

[ 可能符合您检索需要的词汇 ]

目的 探讨双能量脑动脉CT血管造影(CTA)在脑动脉瘤诊断中的价值.方法 以数字减影血管造影(DSA)结果为金标准,回顾性分析30例经DSA证实为脑动脉瘤患者的双能量脑动脉CTA影像学特点,比较双能量脑动脉CTA和DSA检查对脑动脉瘤诊断准确性.结果 双能量脑动脉CTA能较好地显示脑动脉瘤的直接征象,对颈内动脉虹吸段的动脉瘤征象显示优于常规脑动脉CTA扫描.对瘤体及瘤颈的测量与DSA有较高的一致性,两种方法比较差异无统计学意义(P>0.05).双能量脑动脉CTA辐射剂量为19.1~25.4(21.7±0.5) mSv.结论 双能量脑动脉CTA能够清晰显示脑动脉瘤的瘤体大小及瘤颈,对脑动脉瘤的诊断有较高的临床应用价值.
Objective To study the value of dual energy cerebral arteries computed tomographic angiography (CTA) in diagnosis of cerebral aneurysm.Methods As a gold standard of digital subtraction angiography (DSA) findings,the dual energy cerebral arteries CTA imaging features of 30 cases confirmed by DSA for cerebral aneurysm were retrospectively analyzed.The diagnosis accuracy of cerebral aneurysm between dual energy cerebral arteries and DSA was compared.Results Dual energy cerebral arteries CTA could display the direct signs of cerebral aneurysms,it played better in the signs of aneurysm of the siphon segment of internal carotid artery than that by conventional cerebral arteries CTA.The measurement of the size and neck by dual energy cerebral arteries CTA had good agreement to DSA,there was no statistical difference (P > 0.05).The radiation dose of dual energy cerebral arteries CTA was 19.1-25.4(21.7 ± 0.5)mSv.Conclusion The dual energy cerebral arteries CTA can show the size and

[ 可能符合您检索需要的词汇 ]

针对电动汽车发展的问题,扼要地分析了电动汽车制动能量回收研究的重要性和必要性,简要分析了电动汽车制动能量回收技术的发展现状。在深入研究电动汽车制动能量回收技术的基础上,提出了基于制动模式的电动汽车制动能量回收方法,介绍了其结构设计,重点论述了相关参数的确定方法。
Aiming at the problem of the development of electric vehicles, the importance and necessity of the research for braking energy recovery of electric vehicle is briefly analyzed. And the current development of the braking energy recovery technology of electric vehicle is briefly analyzed. On the basis of deeply study of braking energy recovery technology of electric vehicles, the method of braking energy recovery of electric vehicle based on the dual braking mode is put forward, and the structural design of the braking energy recovery system is introduced, and focused on the method for determining the relevant parameters.

[ 可能符合您检索需要的词汇 ]

目的:评价源CT单能量成像技术在骨折后金属内固定术后的应用价值。方法对48处不同部位骨折内固定术后43例患者采用西门子(Siemens)公司生产的Somatom Definition型源多层螺旋CT进行双能量扫描,并将扫描所得到的双能量数据调入工作站Dual-Energy软件内,应用Monoenergetic处理。根据软件所提供的光子能量范围,采用不同的光子能量对数据进行处理,将上述数据与用于常规诊断的120 KV融合图像应用相同的多平面重组、容积再现技术进行重组。由两位医生对以上图像的质量进行评价,并进行比较。结果120 KV时,有45处内固定物有条纹伪影。在80 KeV、120 KeV、160 KeV条件下,图像质量均好于120 KV,其中80 KeV条件下,7处内固定处没有伪影,41处内固定部位仅在金属厚重的部位有少量伪影。结论源CT的单能量成像技术可以显著提高图像质量,并降低金属内固物产生的伪影。而且80 KeV的光子能量可以提供最佳的图像质量。
Purpose To evaluate the value of dual energy CT techniques with monoenergy after fracture fixation with metal. Materials and Methods 48 different parts of the fracture fixations of 43 patients were included in this study. Dual energy scan was performed at dual energy multislice spiral CT (SomatomDefinition, Siemens), dual energy date was transferred to the Dual Energy software, Monoenergetic was appled for processing. Different photon energies that according to the photon energy range which the software provided for data processing, the data above and the 120 KV routine diagnostic fusioned imaging were restructure by the same multiplanar reformation (MPR), volume rendering (VR) technique respectively. Two doctors evaluated and compared the quality of the images. Results 45 fixtures had striped artifacts when 120KV. In 80KeV, 120 KeV, 160KeV conditions, the image quality was better than 120KV, 7 fixtures artifacts disappeared when under 80KV, and only at the part of heavy meta

[ 可能符合您检索需要的词汇 ]

在对能量回馈单元的研究中,分析PWM整流电路的拓扑结构、工作原理和数学模型,并选出实用且便于数字实现的控制方法,设计闭环控制的直接电流控制方案。给出了主电路和控制电路的设计思路,并且基于MATLAB/Simpower Systems的仿真验证了PWM变频器的能量回馈单元具有较好的能量回馈功能。
In the research of energy feedback unit , the PWM rectifier circuit ’ s topology structure , workingprinciple and mathematical model were analyzed; and though selecting practical and digital control method , the DC control scheme which boasting of double closed-loop control was designed , including the ideas for de-signing main circuit and control circuit;and MATLAB/Simpower Systems simulation verifies the better energy feedback function of the dual-PWM inverter energy feedback unit .

[ 可能符合您检索需要的词汇 ]

本文介绍了压电振动能量采集器的工作原理,阐述了振动能量采集器中的单/晶片、Rainbow型、Cymbal型、褶皱型等几种常见和新研发的压电换能元件的结构形式和相应特点。然后,针对如何提高压电振动能量采集器的环境适应能力,介绍了振动能量采集宽频带和多方向两个研究方向,以及国内外在这两个方面的最新研究进展。着重阐述了压电振动能量采集器的拓宽频带宽度、调整共振频率等宽频带能量收集的实现方法,以及非线性磁力耦合结构、立方体-球结构、蒲公英状结构等多方向能量收集的实现方式。最后,对多方向宽频带压电式振动能量采集器的发展趋势进行了展望。
The principles of multi-directional wideband piezoelectric vibration energy harvesters are introduced in this paper. The structures and their characteristics of several traditional and newly developed piezoelectric energy conversion elements used in the vibration energy harvesters are presented, such as Unimorph/Bimorph, Rainbow, Wrinkled and Cymbal type. Afterwards, two research fields of multi-directional and wideband vibration energy harvesting to improve the environmental adaptability are introduced, along with their recent research advances at home and abroad. For wideband vibration energy harvesting, such methods as bandwidth broaden and resonance frequency tuning are elaborated, and for the other field, three structures, namely, nonlinear magnetic coupling, cube-sphere and dandelion-like structure are demonstrated. Finally, the trend of development of the multi-directional wideband piezoelectric vibration energy harvesting technology is prospected.

[ 可能符合您检索需要的词汇 ]

目的:以常规颅脑 CTA 为对照,研究双能量 CT 单能谱成像用于颅内动脉瘤颈夹闭术后评估的最佳能量范围。方法:对36例患者40组双能量数据进行回顾性分析。采用双能量单能谱软件在60~100 keV 之间每隔10 keV 值进行单能量图像重组,平均加权120 kV 为常规 CTA 图像,共6组图像。分别测量每组图像伪影影响最重的脑组织和血管CT 值,评估线束硬化伪影和血管对比度,并对单能量和 CTA 图像质量进行主观评价。结果:60~100 keV 之间单能量图像的动脉瘤夹金属伪影分别为(116.9±73.0)、(72.4±37.3)、(49.8±27.0)、(34.8±20.7)和(26.7±18.2)HU。常规CTA 图像的硬化伪影(62.5±31.6)HU 与70~80 keV 单能量图像差异无统计学意义(P>0.05),80~100 keV 的单能量图像硬化伪影低于常规 CTA。60~100 keV 单能量图像的血管对比度分别为(301.9±74.9)、(217.6±54.2)、(163.8±41.8)、(126.9±34.2)和(103.1±46.1)HU,常规 CTA 的血管对比度(183.5±48.8)HU 与70~80 keV 单能量图像差异无统计学意义(P>0.05)。60~100 keV 和常规 CTA 图像质量为优和良的比例分别为20.0%、47.5%、85%、35%、15%、65%。结
Using conventional CTA as control,to explore the optimal energy range for mono-energetic ima-ging of the dual-energy CT to evaluate the postoperative patient with intracranial aneurysm clipping.Methods:40 sets of du-al energy CT data from 36 patients were analyzed retrospectively.The dual-energy CT data were processed by using the mono-energetic software.Then single energy images were generated every 10keV ranging from 60 to 100 keV.The average weighted 120kV was set as conventional CTA image for comparison.In order to assess the beam hardening artifacts and vascular contrast,the CT value of cerebral tissue and blood vessels were measured,ROI were set on regions where were most severe affected by hardening artifacts.Reconstructed single energy images were assessed by two experienced radiolo-gists blindly.Results:The CT value of metal hardening artifact of aneurysm clip were (116.9 ± 73.0 ),(72.4 ± 37.3 ), (49.8±27.0),(34.8±20.7)and (26.7±18.2)HU for each group ranging fr